EasyManuals Logo

INVT BPD0K7TN User Manual

INVT BPD0K7TN
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
BPD series PV pumping inverter Commissioning guide
68
6.5 Flow chart of the commissioning
3PH pump
motor
Power up the BPD
inverter after the wiring
is checked to be okay
P00.18=1
1PH pump
motor whose
capacitors can
be removed?
P02.00=0
Set pump
motor
parameters
Water
pumping
status okay?
Run
automatically
?
P00.01=1P05.01=1
Run manually:
P00.01=1, P05.01=0,
P05.04=1, Close S4
P00.13=1
P02.00=1
P04.34=0x01
Set pump
motor
parameters
P02.00=1
Set pump
motor
parameters
Y
N
Y
N
Y
N
Y
N
PV Input only?
P15.29=2
AC Input only?
P15.29=1
PV/AC Auto switch:
P15.29=0
Hit "Run" on
Keypad
P02.04=200
Y
N N
Y
Start
End
Figure 6.4 Commissioning flow chart

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT BPD0K7TN and is the answer not in the manual?

INVT BPD0K7TN Specifications

General IconGeneral
BrandINVT
ModelBPD0K7TN
CategoryInverter
LanguageEnglish

Related product manuals