Loading...
Goodrive20 inverters Function Parameters
61
Function
code
Name Detailed instruction of parameters
Default
value
Modify
P07.27
Current fault
type
0:No fault
1: OUt1
2: OUt2
3: OUt3
4:OC1
5:OC2
6:OC3
7:OV1
8:OV2
9:OV3
10:UV
11:Motor overload(OL1)
12:The inverter overload(OL2)
13:Input side phase loss(SPI)
14:Output side phase loss(SPO)
15:Overheat of the rectifier module(OH1)
16:Overheat fault of the inverter module(OH2)
17:External fault(EF)
18:485 communication fault(CE)
19:Current detection fault(ItE)
20:Motor antotune fault(tE)
21:EEPROM operation fault(EEP)
22:PID response offline fault(PIDE)
23: bCE
24:Running time arrival(END)
25:Electrical overload(OL3)
26PCE
27UPE
28DNE
29~31:Reserved
32: ETH1
33: ETH2
34:Speed deviation fault(dEu)
35:Maladjustment(STo)
36: Underload fault(LL)
P07.28
Previous fault
type
P07.29
Previous 2 fault
type
P07.30
Previous 3 fault
type
P07.31
Previous 4 fault
type