Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-132-
Function
code
Name
Description
Default
value
Modify
P01.33
Starting
frequency of
braking for
jogging to stop
0P00.03
0.00Hz
P01.34
Delay to enter
sleep
03600.0s
0.0s
P02––Parameters of motor 1
Function
code
Name
Description
Default
value
Modify
P02.00
Type of motor 1
0: Asynchronous motor
1: Synchronous motor
0
P02.01
Rated power of
asynchronous
motor 1
0.13000.0kW
Depend
on model
P02.02
Rated frequency
of asynchronous
motor 1
0.01HzP00.03 (max. output frequency)
50.00Hz
P02.03
Rated speed of
asynchronous
motor 1
160000rpm
Depend
on model
P02.04
Rated voltage of
asynchronous
motor 1
01200V
Depend
on model
P02.05
Rated current of
asynchronous
motor 1
0.86000.0A
Depend
on model
P02.06
Stator resistance
of asynchronous
motor 1
0.001–65.53
Depend
on model
P02.07
Rotor resistance
of asynchronous
motor 1
0.001–65.53
Depend
on model
P02.08
Leakage
inductance of
asynchronous
motor 1
0.16553.5mH
Depend
on model
P02.09
Mutual
inductance of
asynchronous
motor 1
0.16553.5mH
Depend
on model
P02.10
No-load current
of asynchronous
motor 1
0.16553.5A
Depend
on model
P02.11
Magnetic
saturation
0.0100.0%
80.0%