Goodrive350 IP55 High-ingress Protection Series VFD Function parameter list
-245-
Function
code
Name
Description
Default
value
Modify
torque value
P93.23
System
rotational inertia
0.00655.35 kg.m
2
0.00
kg.m
2
P93.24
Frequency
change rate
-99.99327.67 Hz/s
0.00 Hz/s
P93.25
Torque
compensation
value of system
rotational inertia
-300.0300.0%
0.0%
P93.26
Reference value
after torque
compensation
-300.0300.0%
0.0%
P93.27
PID output
torque
-300.0300.0%
0.0%
P93.28
Final output
torque
-300.0300.0%
0.0%
P93.29
Measured
tension
030000N
0N
P93.30
Number of
material turns on
the reel
-10032767
0
P93.31
Length of
material on the
reel
065535m
0m
P93.32
Length
increment
0.06553.5m
0.0m