Goodrive100-PV Series Solar Pumping VFD Function parameters
41
Function
code
Name
Detailed illustration of parameters
Default
Modify
Full water alarm (A-tF)
Water-empty alarm (A-tL)
P08 Group Enhanced functions
P08.28
Times of fault
reset
010
5
P08.29
Interval time of
automatic fault
reset
0.13600.0s
10.0s
6.2 Parameters of special functions
Function
code
Name
Detailed illustration of parameters
Default
Modify
P11 Group Protective parameters
P11.00
Phase loss
protection
0x0000x011
LED ones:
0: Input phase loss software protection
disabled
1: Input phase loss software protection
enabled
LED tens:
0: Output phase loss software
protection disabled
1: Output phase loss software
protection enabled
LED hundreds:
Reserved
000111
Depend
on model
P11.01
Frequency
decrease at
0: Disable
1: Enable
0

Related product manuals