Goodrive100-PV Series Solar Pumping VFD Recommended solar modules
72
Solar pumping VFD model
Open-circuit voltage degree of solar module
37±1V
45±1V
Module
power±5Wp
Modules per
string *
strings
Module
power±5Wp
Modules per
string * strings
GD100-090G-4-PV
250
18*22
300
15*22
GD100-110G-4-PV
250
18*27
300
15*27
GD100-132G-4-PV
250
18*38
300
15*38
GD100-160G-4-PV
250
18*46
300
15*46
GD100-185G-4-PV
250
18*53
300
15*53
GD100-200G-4-PV
250
18*57
300
15*57
B.2 Recommended configuration for VFDs with the boost module
PP100-3R2-PV
+
Solar pumping VFD
Max. DC
input
current
Open-circuit voltage degree of solar module
37±1V
45±1V
(A)
Module
power±5Wp
Modules per
string * strings
Module
power±5Wp
Modules per
string * strings
GD100-0R4G-SS2-PV
12
250
4*1
300
3*1
GD100-0R7G-SS2-PV
12
250
5*1
300
4*1
GD100-1R5G-SS2-PV
12
250
8*1
300
7*1
GD100-0R4G-S2-PV
12
250
4*1
300
3*1
GD100-0R7G-S2-PV
12
250
5*1
300
4*1
GD100-1R5G-S2-PV
12
250
8*1
300
7*1
GD100-1R5G-2-PV
12
250
8*1
300
7*1
GD100-2R2G-2-PV
12
250
13*1
300
11*1
GD100-0R7G-4-PV
12
250
5*1
300
4*1
GD100-1R5G-4-PV
12
250
8*1
300
7*1
GD100-2R2G-4-PV
12
250
13*1
300
11*1

Related product manuals