Goodrive100-PV Series Solar Pumping VFD Function parameters
55
Function
code
Name
Detailed illustration of parameters
Default
Modify
factory delivery) as model -2, P15.39
must be set to 2.
0: -SS2 220V; single-phase input;
single-phase output
1: -S2 220V; single-phase input;
three-phase output
2: -2 220V; three-phase input;
three-phase output
3: -4 380V; three-phase input;
three-phase output
Setting range: 03
P17 Group State viewing
P17.38
Current of the
main winding
It is the current of the main winding
when applying capacitance-removing to
control the single phase motor.
0.00100.00A
0.0A
P17.39
Current of the
secondary winding
It is the current of the secondary
winding when applying
capacitance-removing to control the
single phase motor.
0.00100.00A
0.0A
P18 Group State viewing special for solar inverters
P18.00
PV reference
voltage
MPPT is implemented at the inverter
side. This value is determined at the
inverter side.
P18.01
Current PV
voltage
It is transferred from the boost module
or equal to the bus voltage.
P18.02
Display of MPPT
The value displays the minimum voltage