Goodrive100-PV Series Solar Pumping VFD Function parameters
40
Function
code
Name
Detailed illustration of parameters
Default
Modify
P07.63
Previous 12 fault
type
22: PID response offline fault (PIDE)
23: Braking unit fault (bCE)
24: Running time arrival (END)
25: Electrical overload (OL3)
26–31:Reserved
32: Grounding short circuit fault 1 (ETH1)
33: Grounding short circuit fault 2 (ETH2)
34: Speed deviation fault (dEu)
35: Maladjustment (STo)
36:Underload fault (LL)
37: Hydraulic probe damage (tSF)
38: PV reverse connection fault (PINV)
39: PV overcurrent (PVOC)
40: PV overvoltage (PVOV)
41: PV undervoltage (PVLV)
42: Fault on communication with the boost
module (E-422)
43: Bus overvoltage detected on the boost
module (OV)
Note: Faults 38–40 can be detected in
boost. The boost module stops working
once after detecting a fault. The boost
module sends back the fault information to
the inverter module in the next data send
back.
Alarms:
Weak light alarm (A-LS)
Underload alarm (A-LL)
●