EasyManua.ls Logo

INVT Goodrive GD300-19-015G-4 User Manual

INVT Goodrive GD300-19-015G-4
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Series Open Loop Vector
Inver ter Special for Hoist
Goodrive300-19
GD3
00- 1
9 5
R
5
G 4
- -

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive GD300-19-015G-4 and is the answer not in the manual?

INVT Goodrive GD300-19-015G-4 Specifications

General IconGeneral
ModelGD300-19-015G-4
TypeInverter
Rated Power15 kW
Output Current30A
Protection LevelIP20
Cooling MethodForced air cooling
Storage Temperature-20°C to +60°C
Communication InterfaceRS485
Operating Temperature-10°C to +50°C
Humidity5% - 95% (non-condensing)
Altitude≤ 1000m

Summary

Safety precautions

Safety guidelines

Outlines general safety guidelines for inverter operation, wiring, and maintenance.

Delivery and installation

Provides safety instructions for handling and installing the inverter.

Commissioning and running

Details safety measures during commissioning and operation of the inverter.

Maintenance and replacement of components

Specifies safety procedures for maintaining and replacing inverter components.

Quick start-up

Environment

Details environmental requirements for inverter installation and usage.

Basic commissioning

Outlines essential steps for basic commissioning before inverter utilization.

Installation guidelines

Standard wiring

Covers the procedures for connecting power and control circuits.

Wiring of main circuit

Details how to connect the main power input and output terminals.

Wiring of control circuit

Explains how to connect control signals and auxiliary power.

Keypad operation procedure

Displayed state of fault

Explains how faults are indicated on the keypad and TRIP LED.

Keypad operation

Explains how to operate the inverter via the operation panel.

How to modify the function codes of the inverter

Details the menu structure and procedure for modifying function codes.

Function parameters

List of function parameters

Provides an overview of how function parameters are organized into groups.

P00 Group: Basic function group

Details basic functions like speed control mode and running command channel.

P00 Group: Basic function group (continued)

Covers motor parameters, AVR, Function restore.

P01 Group: Start-up and stop control

Details parameters related to starting and stopping the motor.

P01 Group: Start-up and stop control (continued)

Covers Restart after power off, Start delay time, 0Hz output selection.

P02 Group: Motor 1

Details parameters for configuring Motor 1.

P02 Group: Motor 1 (continued)

Covers Motor overload protection and correction coefficient.

P03 Group: Vector control

Details parameters for vector control mode.

P03 Group: Vector control (continued)

Covers Lowest weakening point, Max voltage limit, Pre-exciting time.

P05 Group: Input terminals

Details parameters for configuring digital and analog input terminals.

P05 Group: Input terminals (continued)

Covers HDI input settings and filters.

P14 Group: Serial communication

Covers Modbus communication settings like address and baud rate.

P14 Group: Serial communication (continued)

Covers common communication faults.

Technical data

Peripheral options and parts

Braking system

Details the importance and selection of braking components.

Select the braking components

Provides guidance on selecting braking resistors and units based on torque and usage.

Related product manuals