Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-64-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
curve by modifying the weakening control coefficient.
The bigger the weakening control coefficient is, the
steeper the weak curve is.
P03.22 is only valid for vector mode 1.
The setting range of P03.22: 0.1~2.0
The setting range of P03.23: 10%~100%
P03.24
Max.
voltage limit
P03.24 set the Max. voltage of the inverter, which is
dependent on the site situation.
The setting range: 0.0~120.0%
100.0%
P03.25
Pre-exciting
time
Preactivate the motor when the inverter starts up.
Build up a magnetic field inside the inverter to
improve the torque performance during the starting
process.
The setting time: 0.000~10.000s
0.300s
P03.26
Weak
magnetic
proportional
gain
0~8000
Note: P03.24~P03.26 are invalid for vector mode
1.
1000
P03.27
Vector control
speed
0: Display the actual value
1: Display the setting value
0
P03.28
Compensation
coefficient of
static friction
0.0~100.0%
Adjust P03.28 to compensate the coefficient of static
friction. Only valid when the running frequency is
below 1Hz.
0
P03.29
Compensation
coefficient of
dynamic
friction
0.0~100.0%
Adjust P03.29 to compensate the coefficient of static
friction. Only valid when the running frequency is
above 1Hz.
0
P04 Group SVPWM control
P04.00
Motor 1 V/F
curve
setting
The function code defines the V/F curve of
Goodrive300-19 motor 1 to meet the need of different
loads.
0