INVT GD100-004G-4-PV User Manual

INVT GD100-004G-4-PV
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Solar Pumping VFD
Goodrive100-PV Series

Other manuals for INVT GD100-004G-4-PV

Question and Answer IconNeed help?

Do you have a question about the INVT GD100-004G-4-PV and is the answer not in the manual?

INVT GD100-004G-4-PV Specifications

General IconGeneral
ModelGD100-004G-4-PV
TypeSolar Pump Inverter
Rated Power4 kW
Output Power4 kW
Output Current9 A
Efficiency98%
Protection ClassIP20
Communication InterfaceRS485
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Output Voltage220/380 VAC
Frequency Range50/60 Hz
Humidity5% to 95% (non-condensing)
Altitude≤1000 m
ApplicationSolar pumping systems

Summary

Safety Precautions

Safety Definition

Defines terms like Danger, Warning, Note, and Qualified Electricians for safety context.

Safety Guidelines

Provides essential safety guidelines for operating and servicing the VFD, including electrical safety.

Product Overview

Product Specifications

Table outlining the technical specifications of the VFD models available.

Rated Specifications

Table detailing the rated performance characteristics of different VFD models.

Installation Guidelines

Mechanical Installation

Covers the mechanical aspects of installing the VFD, including environmental conditions.

Standard Wiring

Details the standard wiring procedures for the main and control circuits of the VFD.

Keypad Operation Procedure

Keypad Introduction

Overview of the keypad layout, LEDs, display zone, and buttons for VFD control.

Keypad Displaying

Explains how the VFD displays information in different states: stopping, running, faults, editing.

Keypad Operation

Describes how to operate the VFD using the keypad, including modifying parameters and setting passwords.

Commissioning Guidelines

Inspection Before Operation

Essential checks to perform before powering on the VFD for the first time.

Trial Run

Procedure for conducting a trial run of the VFD and pump system.

Parameter Settings

Guide on how to access and modify VFD parameters, including keypad control mode.

Function Parameters

P02 Group: Motor 1 Parameters

Parameters for configuring motor-specific settings like type, power, frequency, and voltage.

P15 Group: Special Functions for PV Inverters

Parameters for PV inverter specific functions, including voltage references and PI control.

Fault Diagnosis and Solution

Inverter Unit U Phase Protection (Out1)

Diagnoses and provides solutions for inverter unit U phase protection faults.

Inverter Unit V Phase Protection (Out2)

Diagnoses and provides solutions for inverter unit V phase protection faults.

Inverter Unit W Phase Protection (Out3)

Diagnoses and provides solutions for inverter unit W phase protection faults.

ACC Overvoltage (OV1)

Diagnoses and provides solutions for ACC overvoltage faults.

DEC Overvoltage (OV2)

Diagnoses and provides solutions for DEC overvoltage faults.

Constant-Speed Overvoltage (OV3)

Diagnoses and provides solutions for constant-speed overvoltage faults.

ACC Overcurrent (OC1)

Diagnoses and provides solutions for ACC overcurrent faults.

DEC Overcurrent (OC2)

Diagnoses and provides solutions for DEC overcurrent faults.

Constant-Speed Overcurrent (OC3)

Diagnoses and provides solutions for constant-speed overcurrent faults.

Bus Undervoltage (UV)

Diagnoses and provides solutions for bus undervoltage faults.

Motor Overload (OL1)

Diagnoses and provides solutions for motor overload faults.

VFD Overload (OL2)

Diagnoses and provides solutions for VFD overload faults.

Appendix A Options and Use

Appendix B Recommended Solar Modules

Appendix C Power Frequency & PV Switching Solution

Appendix D Dimension Drawings