Goodrive100-PV Series Solar Pumping VFD Function parameters
55
Function
code
Name
Detailed illustration of parameters
Default
Modify
factory delivery) as model -2, P15.39
must be set to 2.
0: -SS2 220V; single-phase input;
single-phase output
1: -S2 220V; single-phase input;
three-phase output
2: -2 220V; three-phase input;
three-phase output
3: -4 380V; three-phase input;
three-phase output
Setting range: 0–3
P17 Group State viewing
P17.38
Current of the
main winding
It is the current of the main winding
when applying capacitance-removing to
control the single phase motor.
0.00–100.00A
0.0A
●
P17.39
Current of the
secondary winding
It is the current of the secondary
winding when applying
capacitance-removing to control the
single phase motor.
0.00–100.00A
0.0A
●
P18 Group State viewing special for solar inverters
P18.00
PV reference
voltage
MPPT is implemented at the inverter
side. This value is determined at the
inverter side.
●
P18.01
Current PV
voltage
It is transferred from the boost module
or equal to the bus voltage.
●
P18.02
Display of MPPT
The value displays the minimum voltage
●