Step 1
Loosen the cable grip on each end of the UV housing (This allows the housing to be
unscrewed without twisting the power cables)
Step 2
Unscrew the end caps at each end of the UV
unit. Some water inside the housing may
escape, so it is advisable to have a suitable
container to hand to catch any spillage.