CEM26/GEM28 Worm Play Identification and Adjustment
Tool needed: a set of metric Allen wrench and a
small flat top screw driver, a pair of nose pliers or
tweezers.
1. After open the RA/DEC ring gear cover to
expose worm assembly and ring gear, exam
the worm assembly movement when hold and
rotating the ring gear.
(1) If the whole worm assembly moves up and
springs back down, this is normal for a
spring loaded worm/gear system
(2) If the whole worm assembly moves left/right,
or even gets free at one end, the hinge(s)
may get loose. Go to next step to fix it.
(3) If only the worm itself is moving freely, the
worm end cap needs be tightened. Please
refer to Step 13 to adjust it.
2. Remove mount motor cover.
3. Carefully unplug the motor cable from the DEC
control board.
4. Release two screws and remove the motor
5. Check the worm assembly to see if both hinge
pins are in position. They should be almost
flash with the bearing.
Hinge pin
(1)
(2)
(3)

Other manuals for iOptron CEM26

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the iOptron CEM26 and is the answer not in the manual?

iOptron CEM26 Specifications

General IconGeneral
Payload Capacity26 lbs (11.8 kg)
RA Worm Wheel180 teeth
DEC Worm Wheel180 teeth
RA Worm1:180 gear ratio
DEC Worm1:180 gear ratio
Power Requirement12V DC
Go2Nova ControllerYes
Tracking RateSidereal, Solar, Lunar
GPSYes
Communication PortsUSB

Related product manuals