Copyright © 2020 IoTecha Corp. All rights reserved.
10
Ground Fault Detection (GM/I) YES
Open Safety Ground Detection Continuously monitors presence of safety (green wire) ground connection
Fault Recovery Interval Non-critical faults are automatically reset after 20 seconds and full internal self-test
Environmental
NEMA/IP Rating (Dust / Moisture) NEMA 3R
IK Rating (Mechanical Impact) IK 10
Altitude 3,500 m (Operating)
Solar Radiation 1120 W/m² (Class 2K4)
Wind Rating 12 Beaufort
Operating Temperature -30°C to +50°C
Storage Temperature -40°C to +60°C