charge the batteries (BATTERY version).
• Open the cowling and use the internal combustion engine starting handle. When the
engine is cold, you also need to use the choke (INTERNAL COMBUSTION ENGINE
with manual pull start).
• Use the lever to activate the drive (fig.C, ref. 2)
• Press the suction button (fig.B, ref. 9).
• Adjust pressure of the centre brush on the floor using the knob (fig. B, ref. 8) according
to the type of floor and dirt to be picked up. Turn it clockwise to increase pressure and
anticlockwise to reduce pressure on the work surface.
• Lower the side brush using the lever (fig. B, ref. 11).
• Start cleaning, manoeuvring the handgrip with the hands and acting on the drive
control.
IMPORTANT
To avoid damaging the surface of the floor to be treated, avoid rotating the brushes
with the machine stationary.
IMPORTANT
Do not pick up wire, string or plastic straps.
IMPORTANT IMPORTANT
Each 30 minutes of work, activate the filter shaker button (fig. C, ref. 4) for 30
seconds to clean the suction filter. During this operation, the suction fan shuts off
automatically.
IMPORTANT
Avoid passing over puddles. If the work surface is wet, you can use the machine
only by turning off the suction fan (fig. C, ref. 2) as damp/wet dirt reduces the
performance of the suction filter.
Emptying the debris bin:
Before emptying the bin, make sure all machine functions are turned off;
IMPORTANT
When emptying the bin, always wear a mask to protect the respiratory tract from
the dust which is always present during this operation.