PLDC01911
Check the detergent tank fill filter is
undamaged and clean.
Check the detergent output filter is
undamaged and clean.
Clean the brush and wash the
microfibre in a washing machine.
Check the squeegee is clean and
the blades are not damaged.
Check the battery charge.
To charge, insert the battery
charger connector into the
connector alongside the
squeegee lifting lever.
REPLACING THE SQUEEGEE BLADES
• release the clip;
• remove the two blade retainers by pushing them towards the outside of the squeegee then extracting them;
• remove the blade;
• reuse the same blade by reversing the edge in contact with the floor until all four edges are worn out, or replace with
a new blade, fitting it onto the screws on the body of the squeegee;
• reposition the two blade retainers by centring the widest part of the slots over the fixing screws on the squeegee
body, then pushing the blade retainers inwards;
• fasten the clip.
AUTOMATIC BRUSH ATTACHMENT
Brush attachment, with the head raised, rest the brushes on the floor at the sides of the head. Push the brushes into the head,
making sure they are aligned with the centring devices in the head. Press the brush button. The machine attaches the brushes
automatically.
Brush release, stop the brushes and the suction motor by pressing the brush and suction motor buttons. Hold the automatic release button
down for at least five seconds and the machine releases the brushes from the head automatically.
TROUBLESHOOTING