109YLS-K
Command Parameter 1 Parameter 2 Comment
# Name
4 WAIT SI LOW Wait for LOW (0) level sig-
nal on input Sync. IN.
SI HIGH Wait for HIGH (1) level sig-
nal on input Sync. IN.
SI LH Wait for rising edge on input
Sync. In.
SI HL Wait for falling edge on in-
put Sync. IN.
Time 0 – 655000
or FBUS
Wait time in ms
5 GOTO Line 0 - 99 SI LOW Jumps to the next line of the
program as long as a LOW
(0) level signal is present at
SI.
Line 0 - 99 SI HIGH Jumps to the next line of the
program as long as a HIGH
(1) level signal is present at
SI.
Line 0 - 99 0 - 32000 Jumps to the specified line
as often specified in parame-
ter 2.
6 OUT SO LOW Sets signal LOW (0) at out-
put Sync. OUT.
SO HIGH Sets signal HIGH (1) at out-
put Sync. OUT.
7 EXTPWR ANALOG - Changes to the analog inter-
face
FBUS - Changes to the fieldbus in-
terface
8 SETCHAN Channel 1 …
n
- Selection of the optical chan-
nel for production with inte-
grated beam switch (only
available in command line 1)
Table18: Modules tab description
| LaserNet software