Information message: Request for basic
status: output power socket status,
temperature and GSM signal
7.1 Thermostat
This feature can be attractive if you wish to ensure activating or deactivating
appliance when temperature threshold is reached.
Typical example is heating activation when temperature is below 20 ˚C and
deactivating when temperature is over 25 ˚C.
(THERMOSTAT=YES, TEMPON=20, TEMPOFF=25)
Other example is airconditioning activation over 28 ˚C and deactivation when
temperature is below 24 ˚C
(THERMOSTAT=YES, TEMPON=28, TEMPOFF=24)
7.2 Temperature calibration
Measured temperature is usually influenced by heating caused by IQsocket
electronics , so built-in thermometer provides usually little higher temperature
as real. For this reason is used temperature calibration constant which is
configured based on global experience to value 4. This calibration can be
changed individually for each monitored environment. Measured temperature is
decreased always by calibration this constant.
Activates sending of information SMS
for each received SMS command,
which was not executed due to any
error.