2009 NETCONS, s.r.o.
Page 12 of 16
When alarm is activated, power
socket is making a call to
preconfigured number. When external
detector is unplugged, alarm is
activated too and is repeated each 60
seconds.
Alarm+421903801
254 – OK
Alarm – NO sensor
Alarm – NO
number!
Activates switched contact/microrelay
on alarm. Can be used for siren or
anything else.
Request for ALARMOUTPUT
configuration
9.2 Temperature alarms
Built-in thermometer can be used to generate temperature alarms after critical
temperature thresholds are reached. IQsocket uses low and high temperature
thresholds which are configured by TEMPON=MAX and TEMPOFF=MIN
commands. Temperature alarm monitoring is activated 10 minutes after
IQsocked is powered on.
Temperature alarms are disabled
In case of maximal temperature
threshold is reached - SMS is sent
In case of minimal temperature
threshold is reached - SMS is sent
In case of mini or maximal temperature
threshold is reached - SMS is sent
Request for temperature configuration
TEMPALARM=(NO),
MAX,MIN,MIX
External detectors
9.3 Generated alerts
There are more ways how to inform you about detected alarm. You can be
alerted by SMS or by phone call on active alarm. Or you can be informed by
SMS on each change of logical INPUT.
Phone call is established to predefined
number in case of new alarm
SMS is sent to predefined number in
case of new alarm
SMS is sent on each logic value change
to predefined number in case of new
alarm
Request for alert configuration
ALERT=(RINGON),
SMS, SMSCHANGE