11. INSTALLATION
All packaging materials are recyclable and should be disposed of in accordance with local regulations. All packaging materials
are recyclable and should be disposed of in accordance with the local regulations. Please destroy "plastic" bags to prevent them
from becoming hazardous to children (suffocation).
11.1 UNPACKING
STORAGE11.2
The appliance, with or without its packaging, must be carefully stored inside warehouses or in areas protected from the weather
and from direct sunlight, at a temperature of between 32 and 104 °F.
11.3 HANDLING
Handling of the equipment must be performed exclusively by a forklift truck of power adequate to the weight of
the same and operated by qualied personnel: during this operation the equipment must always be positioned
on the dedicated pallet supplied.
11.4 ENVIRONMENTAL CONDITIONS
ATTENTION
A dry room that can be ventilated is the suitable location for the appliance's installation. There should be a good air
ow around the compressor/condensing unit. Therefore the area around the unit should not be obstructed by boxes
or other objects. Place the equipment away from sources of heat (radiators, heaters of any kind, etc.) and far from
the inuence of continuous air movement (caused by fans, air conditioning units, etc.). If it is unavoidable to install
near a heat source, use a suitable insulating plate. Also avoid exposure to direct solar irradiation; all of this causes
the temperature inside the refrigerated compartment to rise with negative consequences on operation and energy
consumption. Do not use the appliance outdoors and do not leave it exposed to rain.
11.5 ELECTRICAL CONNECTION
ATTENTION
Check that the network voltage matches the one displayed on the identication plate of the appliance, and that the
power is adequate. Check on the socket that the power supply voltage provides rated voltage (±10%) when you start
up the compressor. The plug should be directly connected to the electrical socket. It is forbidden to connect the plug
to the socket by means of multiple socket extensions or adaptors. The plant power supply socket must be tted with
a disconnection device from the mains electricity (dimensioned to the load and in compliance with Standards in
force), which guarantees complete disconnection in category III (3) over-voltage conditions and therefore protects the
circuits against earth faults, overloads and short circuits. Do not route the electricity cable in passageways.
ATTENTION
Remember that earthing is necessary and is a requirement imposed by law.
104 °F MAX
32 °F MIN