Caution:
The wiring should be checked
completely by your dealer
every year to avoidfire
hazards.
Note:
As the fuel piping and electric
wiring fatigue as time
passes,they should be re-
placed every other year. Their
early replacement is recom-
mended.
o
Replacement
of
fuses
Fuse box (A):
Eleven fuses are installed in
the fuse box (A). A blown
fuse should be replaced with a
new one
of
the same capacity
without fail. Installation
of
a
fuse
of
bigger capacity may
cause burning
of
electrical
apparatus or wiring.
2 3 4 5 6
-
-c
«
~[
<
« «
~
g
0
~
0
,.---
"
-----
[Q]
~
[Q]
"---
-c
«
<
-c
0
----
~
0 0 0
-
-
..
7 8 9
10
(1)
Fuel
pump/Spare
power
supply
(15A)
(2)
Warning
flash
IighUSpare
power
supply
(30A)
(3)
Horn/Spare
power
supply
(30A)
(4)
Stop
light
(lOA)
(5)
Turning
signal
(15A)
(6)
Work
light
(30A)
(7)
Taillight
(RH)
(lOA)
(8)
Taillight
(LH)
(lOA)
(9)
Side
clearance
light
(LH)(lOA)
(10)
Side
clearance
light
(RH)
(lOA)
Fuse box (B):
4 fuses for the head lamps are
housed in the fuse box (B):
SA
x4
Fuel
pump
fuse:
A tube fuse (2A) is installed
in the wiring for the fuel
pump.
-39-
TU320F
&
TU324F
Fusible links:
Two fusible links are installed
in the wiring.
A fusible link is installed to
protect the whole wiring.
Therefore, when the link is
shorted out, no current flows
through the whole circuit.
When the link has been
melted, be sure to locate the
cause and correct it. And then
install our genuine fusible
link.
To check fusible links for
melting-A
normal one
cannot be identified. But once
melted, it can be identified by
the discoloration and swelling
of its cover.
Note:
• When a fuse is blown, be sure
to locate the cause and cor-
rect it.
• Never use a wire instead
of
a
fuse.