EasyManua.ls Logo

Isotemp Basic - Connections; Material; Hoses

Isotemp Basic
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Slim Square without and with thermostat mixer valve
Fig. 6
45°
45°
0-90°
45°
45°
Slim Square
Slim Square alternative mounting posi-
tions.
Remember, safety valve always at the
lowest position.
4. Connections
4.1 Material: Use only fi ttings and accessories made
of non-corrosive material such as brass or stainless
steel. Avoid plastic fi ttings on the water heater depend-
ing on the heat, unless they are specially made for this
purpose. This is important, a leak in this area can cause
a sudden engine overheat as well as a dangerous hot
water spray.
4.2 Hoses: For the engine connections, use heat re-
sistant (100°C / 210°F) reinforced rubber hoses,
Fig. 7
resistant to anti-freeze and pressure approved
for 5 bar / 70 psi. For the fresh water, cold inlet and
warm outlet, use heat resistant fresh water hoses (food
industry quality). They shall be rated 8 bar / 115 psi.
Fasten the hoses carefully with hose clamps. Seal the
threaded connections with e.g. Loctite 577 or Bondline
T777.
Hose nipples with thread G½” (½”BSP) fi ts the
connectors on the water heater.
001017
001018
6