www.123filter.com | (678) 261-7611 sales@ispringfilter.com | Rev 03/14 | p1/10
User Manual
iSpring 6-Stage Reverse Osmosis System #RCC7AK
Model Number RCC7AK Production Rate 283.88 L/d (75 gpd)
Recovery 26.76% Efficiency 15.82%
Temperature 40°F - 100°F Pressure 40-80 psi
System tested and complied with NSF/ANSI Standard 58 for the reduction of substances.
Influent Challenge
Concentration
Maximum Allowable
Concentration
Average Percent
Reduction
Arsenic (pentavalent) 50 ppb 10 ppb 97.9
Cysts Minimum 50,000/mL 110 #/mL >99.99
Fluoride 8.0 mL ± 25% 1.5 mL 96.5
Lead 0.15 mL ± 25% 0.010 mL 98.1
TDS (Total Dissolved Solids) 740 187 mL 96.7
Question and Answer IconNeed help?

Do you have a question about the Ispring RCC7AK and is the answer not in the manual?

Ispring RCC7AK Specifications

General IconGeneral
Stages6
Tank Capacity3.2 gallons
Filter TypeReverse Osmosis
pH EnhancementYes
Operating Temperature40-100°F
Warranty1-Year Limited Warranty
Filtration Capacity75 Gallons Per Day (GPD)
Filter Life6-12 months
System Weight20 lbs
System Dimensions15 x 8 x 18 inches

Summary

Introduction

Filter Cartridge Replacement Schedule

Limited Warranty

System Diagram

Parts Index

How to Use Quick-Fitting

Tips for Drilling a Hole on Sink or Counter-top

Tips for Changing Filter Cartridges

System Installation

Install the Vertical Filters: Stages 1, 2, and 3

Install sediment, GAC, and CTO filters into housings.

Install Reverse Osmosis Membrane

Insert the RO membrane into its housing.

Install 3/8” Feed Water Adapter (AFW)

Connect the system to the cold water supply.

Install RO Drinking Faucet

Mount and connect the dedicated RO faucet.

Install Tank Shut-off Valve (TSV)

Connect the valve to the storage tank.

Install Drain Saddle

Attach the drain connection to the sink's drain pipe.

Tubing Hook up

Connect all internal and external tubing lines.

System Start Up

Procedures for initial system operation and flushing.

iSpring Warranty Registration Form