iSYSTEM, October 2016 60/69
26-pin KEL Renesas V850 Cable Adapter
Ordering code
IC50172
This adapter is used to connect the iC5000 / iC5500 / iC6000 development system to Renesas V850 based target.
It connects to Debug/Trace module on one side and to the target debug connector on the other side. It can be
used for targets featuring 26-pin KEL target debug connector with V850 pinout.
The following pinout is valid on the target side:
Signal
direction
Signal description
Signal
Pin
Pin
Signal
Signal description
Signal
direction
Ground
GND
B1
A1
Reserved
Reserved
Ground
GND
B2
A2
Reserved
Reserved
Ground
GND
B3
A3
Reserved
Reserved
Ground
GND
B4
A4
Reserved
Reserved
Ground
GND
B5
A5
Reserved
Reserved
Ground
GND
B6
A6
Reserved
Reserved
Ground
GND
B7
A7
DDI
N-Wire
O
Ground
GND
B8
A8
DCK
N-Wire
O
Ground
GND
B9
A9
DMS
N-Wire
O
Ground
GND
B10
A10
DDO
N-Wire
I
Reserved
Reserved
B11
A11
DRST
N-Wire
O
Reserved
Reserved
B12
A12
RESET
Reset
O
I
Reference Voltage
VTRef
B13
A13
FLMD0
Flash Mode
O
26-pin Renesas V850 target pinout
Note: 26-pin KEL V850 Cable Adapter features resettable fuses on all connected signals. These fuses protect
debug signals against overcurrent and cycle back to a conductive state after the excessive current fades away.
This adapters ends with a KEL connector (part number 8825E-026-175). Normally, the target side has KEL
connector, part number 8830E-026-170S populated. For more details see 8825E Series at http://www.kel.jp/.