EasyManua.ls Logo

ITech IT6300

ITech IT6300
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Commands
Copyright© Itech Electronic Co., Ltd. 15
Command syntax
SYST:LOC
Arguments
None
SYSTem:RWLock[:STATe]
This command is transmit through RS232 interface, the same function as
SYSTem:REMote, but the difference is: this command can lock “LOCAL”
button as well. When this command is executed, the “Local” button can’t
switch to local control mode.
Command syntax
SYST:RWL
Arguments
None
SYSTem:COMMunicate:GPIB:RDEVice:ADDRess
This command is used to set the device address of the GPIB communication.
Command syntax
SYSTem:COMMunicate:GPIB:RDEVice:ADDRess {<NR1>}
Arguments
1~30
Query syntax
SYSTem:COMMunicate:GPIB:RDEVice:ADDRess?
Returns
<NR1>
SYSTem:COMMunicate:LAN:CURRent:ADDRess
This command is used to set IP address of power supply. (LAN related
instructions only apply to IT6300C series instruments)
Command syntax
SYSTem:COMMunicate:LAN:CURRent:ADDRess <STR>
Arguments
<STR>
Unit
None

Table of Contents

Related product manuals