Output Commands
Copyright© Itech Electronic Co., Ltd. 33
Arguments
num|MIN|MAX|DEF
Setting range: 0~rated value
Unit
V mV kV
*RST Value
MIN
Query syntax
[SOURce:]VOLTage[:LEVel]?
Arguments
[MIN|MAX]
Returns
<NR2>
[SOURce:]VOLTage[:LEVel]:UP[:IMMediate][:AMPLitud
e]
This command is used to increase a voltage step for voltage channel.
Command syntax
[SOURce:] VOLTage[:LEVel]:UP[:IMMediate][:AMPLitude]
Arguments None
Related Command
[SOURce:]VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]
[SOURce:]VOLTage[:LEVel]:DOWN[:IMMediate][:AMPL
itude]
This command is used to decrease a voltage step for voltage channel.
Command syntax
[SOURce:] VOLTage [:LEVel]:DOWN[:IMMediate][:AMPLitude]
Arguments
None
Related Command
[SOURce:]VOLTage[:LEVel][:IMMediate]:STEP[:INCRement]