[SOURce:]FALL[:LEVel] 
This command is used to set the voltage falling time of power supply. 
Command syntax:[SOURce:] FALL [:LEVel] <NRf> 
unit:s 
parameter:0~65.535 
inquiry syntax:[SOURce:] FALL [:LEVel]? 
Return parameter:0~65.535 
 
  [SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] 
This command is used to set the output current value. 
Command syntax:[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf> 
parameter:MIN TO MAX|MIN|MAX|DEF 
unit:A |mA |uA 
inquiry syntax:[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? 
parameter:None 
return parameter:<NRf> 
 
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]{<current level>  | MINimum | 
MAXimum } 
This command is used to set a current value to be triggered.Different from general current 
value,this value will be effective until it receives a trigger signal.Sending CURRent command 
will not impact this command’s current setting value.Sending inquiry command will return the 
original setting value. 
Command syntax:[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]  <NRf> 
parameter:MIN TO MAX|MIN|MAX|DEF 
unit:A 
inquiry syntax:[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]? 
Return parameter:<NRf>