[SOURce:]FALL[:LEVel]
This command is used to set the voltage falling time of power supply.
Command syntax:[SOURce:] FALL [:LEVel] <NRf>
unit:s
parameter:0~65.535
inquiry syntax:[SOURce:] FALL [:LEVel]?
Return parameter:0~65.535
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
This command is used to set the output current value.
Command syntax:[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf>
parameter:MIN TO MAX|MIN|MAX|DEF
unit:A |mA |uA
inquiry syntax:[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
parameter:None
return parameter:<NRf>
[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]{<current level> | MINimum |
MAXimum }
This command is used to set a current value to be triggered.Different from general current
value,this value will be effective until it receives a trigger signal.Sending CURRent command
will not impact this command’s current setting value.Sending inquiry command will return the
original setting value.
Command syntax:[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] <NRf>
parameter:MIN TO MAX|MIN|MAX|DEF
unit:A
inquiry syntax:[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]?
Return parameter:<NRf>