Specications
SpecsSpecs
Specications IT6720
Output Rating Voltage 0~60V
Current 0~5A
Power 100W
Load Regulation Voltage <0.01%+3mV
Current <0.01%+3mA
Line Regulation Voltage <0.01%+3mV
Current <0.1%+3mA
Programming Accuracy Voltage <0.05%+10mV
Current <0.2%+2mA
Read back Accuracy Voltage <0.05%+10mV
Current <0.1%+2mA
Ripple Voltage <2mV rms
Current <5mA rms
Dimension W*H*D 88*175*282(mm)
Weight Net <2.5Kg
If the outputs is disabled:
1: Check whether voltage and current settings are zero, if so, reset voltage and current value.
2: Check whether the indicator is lit on, if so, press to enable the outputs.
3: Check whether the indicators are lit on, if so, please reset according to the mentioned
OVP/OCP/OCP means.
If the keypad is disabled, check whether the indicator lock is lit on, if so, unlock the
keypads as the above means.