9
SECURE MOUNTING:
Ensure that the charger is securely mounted to prevent any movement or
vibrations during operation.
ELECTRICAL CONNECTIONS:
Ensure correct connection of the iTECHBC25 to the power source and the
batteries it will be charging. Utilise the appropriate wire gauge and connectors to
minimise voltage drop and guarantee safe operation.
MAINTENANCE:
Ensure that the iTECHBC25 is turned off and disconnected from both the battery
and the 240V AC input while conducting any maintenance.
Periodically inspect the charger and the surrounding area to ensure it remains
dry, clean, and free from obstructions. Check for any signs
of damage or wear and
address them promptly.
Also, clean the exterior with a dry cloth to prevent the accumulation of dust and
dirt. Additionally, inspect and tighten the DC output terminal screws as needed.
SELECTION OF CABLE SIZE:
The iTECHBC25 charger cables may not be long enough for your application. If they
need extending, please refer to the table below with the recommended wire sizes.
You can select wires that are equal to or larger than the recommended sizes.
Input Length
Solar Positive
Alternator Positive
Output Positive
Ground
0-3M 3-6M 6-9M
6mm
10AWG) 10mm 8AWG) 16mm 6AWG)