7.2. DRAIN FORCE
The bin is flooded
The check valve is blocked
Clean or Replace it
The pump is broken
Replace it
The electrodes do not detect water
Disassemble and clean, if
problem persist, replace it
The pump is always turn on
The electrodes detect water even if
there is no water
Disassemble and clean the
electrodes