Power Units (All Potted Models)
5200095 Rev C
High Voltage Connections for Cable with Optional Stainless Steel Shielding
Some static eliminating equipment is equipped with shielded high voltage cable and has
a separate ground wire and must be connected to the ground terminal on the power unit.
Insert the spring-loaded connector into the high voltage output terminal of the power unit
and finger-tighten.
Ionizing air guns and certain HS Nozzles with shielded cable are shipped with all
connections completed by the factory as shown in Figure 1 below. For equipment that
requires on site-connections, refer to the assembly procedures below.
NOTE – Do not alter the length of shielded cable. Should this become necessary,
contact Simco-Ion for further information.
1. Insert the high voltage cable end through the angle bracket (item 6) of the power unit.
2. Install and tighten hex nut (item 8).
3. Install male section of nylon compression fitting (item 9a) as shown and tighten
securely onto the hex bushing (item 5).
4. Install and tighten female section of the compression fitting (item 9b).
5. Install the spring-loaded high voltage connector (item 11) on the high voltage cable
as described in Section 2.
6. Insert the spring-loaded high voltage connector into the high voltage output terminal
of the power unit. Finger tighten.
7. Install strain relief clamp (items 1, 2, 3).