ManagerIQEasy_QM_9752103070_NL_D_GB_F_V1_0 11
Danger:
- Make sure that the equipment is properly earthed. Earthing is necessary to ensure proper
and safe operation and to prevent electric shocks upon contact.
The AC version is earthed through the power cable. Plug this into an earthed outlet.
With the 24 V DC version, the earthing connector of the 24 V power connector has to be
connected to the machine earthing or an earthed machine part.
- To guarantee safe operation, keep the Manager IQ Easy free of dirt, dust and moisture.
- The device may only be serviced by qualified Simco-Ion staff.
Note:
- Making changes, adjustments etc. without prior written consent or carrying out repairs using
non-original parts will invalidate the device’s guarantee.
Except for the 230 AC input connector, all connectors for the devices and various I/O have
signals that are working on a safe 24 V DC.
That is why all these inputs and outputs can be connected and disconnected safely while the
Manager IQ Easy is operating.
3. Technical specifications
100 – 240 V AC nom. (90 – 305 V AC)
50 – 60 Hz nom. (47 – 63 Hz)
300 W (100 – 240 V AC version)
360 W (@15 A) (24 V DC version)
Operating temperature
Installation
Device output 100-240 V AC
0 – 55 °C
Free of dust and vibration
24 V DC 3 A max. per port, total max. 9 A
Device output 24 V DC version
Machine I/O
24 V DC 3 A max. per port, total max. 13 A
Analog input
0-10 V 0,6 mA / 0- 20 mA / 4- 20 mA
OE/OC 24 V DC nom. Max. 30V 25 mA
3x USB 2.0
1x RJ45 8-pin connector