Settings Customer level
6 720 643 415 (2010/03)
18
Room temperature program when there are room
sensors:
>> Room temperature program
>>> Active program
If a program is selected, the following (if the menu
button is turned) is displayed:
>>> View/edit active program
>>> Room temperature normal
B Set the desired set point for the room temperature.
>>> Room temperature exception
B Set the temperature that should apply as exceptional
temperature in the program.
The menu is displayed only if Program 1 or Program
2 has been selected.
>>> Copy to all heating circuits
B Select Yes to have the same control for all installed
circuits.
The menu is displayed only under Circuit 1.
Room temperature program when there is no room
sensor:
>> Room temperature program
>>> Active program
>>> View/edit active program
The same as when there is a room sensor, see above.
>>> Room temperature normal
B Set the measured value in the room.
The indicated value is used by temperature programs
to calculate the difference between normal and
exceptional temperature.
>>> Temperature increase/decrease
B Use this function to adjust the room temperature so
that the normal room temperature (see the previous
menu) becomes the desired temperature.
B Use this function to simply increase or decrease the
heat when there are no room sensors.
– gives approx. 1 °C lower room temperature.
– gives approx. 0.5 °C lower room temperature.
+ gives approx. 0.5 °C higher room temperature.
++ gives approx. 1 °C higher room temperature.
>>> Room temperature influence
Setting is carried out in the same way as in the menu
Room sensor
(Æ Chapter 10.2). The setting is used in the
temperature program to calculate how the flow line
temperature is affected when exceptional temperature
should apply.
>>> Room temperature exception
The same as when there is a room sensor, see above.
>>> Copy to all heating circuits
The same as when there is a room sensor, see above.
Factory setting 20.0 °C
Lowest value 10.0 °C
Highest value 35.0 °C
Tab. 16 Room temperature, normal
Factory setting 17.0 °C
Lowest value 10.0 °C
Highest value 30.0 °C
Tab. 17 Room temperature, exception
Factory setting No
Alternative No/Yes
Tab. 18 All circuits
Factory setting 20.0 °C
Lowest value 10.0 °C
Highest value 35.0 °C
Tab. 19 Room temperature, normal
Factory setting =
Alternative , – , =, +, ++
Tab. 20 Room temperature increase/decrease
It always takes some time for a change of a
heating setting, e.g. an increase or decrease
in room temperature, to apply. The same
applies in the event of a quick change of the
outdoor temperature. This is why you
should always wait for at least 24 hours
before making a new change.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IVT Greenline HE C6-C11 and is the answer not in the manual?

IVT Greenline HE C6-C11 Specifications

General IconGeneral
BrandIVT
ModelGreenline HE C6-C11
CategoryHeat Pump
LanguageEnglish

Related product manuals