EasyManuals Logo
Home>IVT>Control Unit>HMC300

IVT HMC300 User Manual

IVT HMC300
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
19
Use the main menu
HMC300 – 6 720 813 192 (2014/10)
5.2.2 Setting of changeover temperature for summer/
winter mode
Heating hot water is not affected by summer/winter mode.
Menu: Summer/winter mode
5.3 Change settings for heating hot water
Menu: DHW
These settings are only available if a hot water system is
installed in the system. The water is then heated in a hot water
heater.
A time program has been set at the factory for heating hot
water. Alternatively the heating of hot water is managed
constantly ( chapter 5.3.2, page 20).
NOTICE: System damage
Do not switch over to summer mode if
there is a risk of frost.
Summer/winter changeover is only active if
Heating/Cooling > Automatic mode has
been set.
Menu
options
Description
Heating/
Cooling
Constant summer mode (= OFF): The
heat pump is not used for heating or
cooling.
Automatic mode: Heating or cooling mode
is activated, depending on the outdoor
temperature. When the outdoor
temperature lies between the two limiting
values the system only provides hot water.
Continuous heating: Cooling mode is not
activated, and the system does not run on
idle.
Continuous cooling : Heating mode is not
activated, and the system does not run on
idle.
Heating
mode off
1)
1) Only available when the outdoor temperature controlled
summer/winter mode is active in respective heating circuit.
When the damped outdoor temperature
2)
exceeds the changeover temperature set here,
the house heating is switched off.
If the damped outdoor temperature falls below
the changeover temperature by 1 °C, the house
heating is switched on. In systems with several
heating circuits this setting applies for the
selected heating circuit.
2) Damped outdoor temperature involves a delayed effect of
the measured outdoor temperature to equalise
temperature variations.
Cooling
mode off
1)
If the outdoor temperature exceeds this set
temperature, the cooling mode starts.
Table 14 Settings for summer/winter mode
WARNING: Scalding risk!
If the temperature for extra hot water is set
higher than 60 °C or if thermal disinfection has
been activated to prevent legionnaires'
disease, the hot water is heated once to over
65 °C. The default setting for the hot water
temperature is 60 °C. With higher settings
there is a risk of scalding from hot water taps.
Make sure a mixer is installed. Ask your
installer if you are unsure how to do this.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IVT HMC300 and is the answer not in the manual?

IVT HMC300 Specifications

General IconGeneral
BrandIVT
ModelHMC300
CategoryControl Unit
LanguageEnglish