24
Use the main menu
HMC300 – 6 720 813 192 (2014/10)
5.4 Settings for heated pool
In this menu you can adjust the settings for heating a pool.
Menu: Pool
5.5 Settings for extra heat source (additional
heat)
If the heat pump cannot deliver enough heat quickly enough
during the winter, or for heating hot water, an extra heating
source is required (additional heat). It is possible to use
additional electric heat, or an extra heat source (gas, oil or
wood heater via a mixing valve).
This menu is only shown when additional heat is installed in the
system.
5.5.1 Time program for extra heat source
If you are not at home, or for any other reason want to have a
lower room temperature, you can reduce your energy
consumption by limiting the effect of the extra heat source.
Menu: Unit > Time program additional heat
5.5.2 Settings for Silent mode of heat pump
If a heat pump has been installed the settings in this menu can
be used to reduce the noise level when the system is in
operation.
Menu: Unit > Silent mode
Menu options Description
Activate pool
heating
If the heating for a pool is activated here,
the pool is heated up.
Pool
temperature
The water in the pool is heated up to this set
temperature.
Allow
additional
heat in pool
mode
If additional heat for pool mode has been
approved the required water temperature
can also be achieved by means of additional
heat if the heat pump cannot deliver enough
heat.
Table 23 Settings for a pool
Menu
options
Description
Time
program
Activate
additional
heat
If the time program for additional heat is
activated the additional heat can only deliver
extra heating in the periods with the mode on.
My time
program
The time program for additional heat can be set
with this menu option.
Reset time
program
The time program for additional heat is reset to
the default settings.
Time
program
min.
outdoor
temp.
If the outdoor temperature is less than this set
temperature the time program for additional
heat is disconnected.
Table 24 Time program for an extra heat source
Menu
options
Description
Silent
mode
If No has been selected the noise level will
not be reduced.
If Auto has been selected the heat pump
starts automatically in silent mode at
22:00. At 6:00 silent mode is switched off
again, i.e. the noise level is reduced from
22:00 to 6:00.
If On has been selected the noise is
reduced continuously.
Min.
outdoor
temperatur
e
If the outdoor temperature is less than this set
temperature the heat pump cancels silent
mode.
Table 25 Settings for silent mode