When an alarm is displayed (“Alarms” are described on page
47), tapping the STEP button will temporarily delete that
measurement from the sequence for the next ten minutes.
When an alarm is displayed, holding the STEP button until the
word OFF appears will delete that measurement from the
sequence for the remainder of the flight.
LF Button
Located on the lower right side near the instrument face.
In Automatic or Manual indexing modes, tapping the LF
button will change to the LeanFind mode.
In Automatic or Manual indexing modes holding the LF
button for three seconds will toggle between Percentage and
Normalize views.
N: Normalize viewP: Percentage view
hold LF button
for 3 seconds
In the LF mode holding the LF button after peak EGT is
found will display peak EGT.
Long Term Memory Option only: in the LF mode tapping the
LF button will mark a data record in memory.
Secondary functions of the LF button include:
In the pilot programming procedure, holding or tapping the
LF button is used to increment or decrement parameter values
and toggle between yes and no answers to questions.
STEP and LF Buttons
Holding both the STEP and LF buttons simultaneously for
five seconds changes to the pilot programming procedure.
Holding both the STEP and LF buttons simultaneously for
five seconds after tapping LF but before beginning to lean
will toggle between Rich of Peak and Lean of Peak
Tapping both the STEP and LF buttons simultaneously in
Manual indexing mode toggles to include or exclude the
For Your Safe Flight Page 11