T, A
OAT+0
OAT-10
OAT 10
This step will be normally be
skipped. See step above.
Adjust the indicated temperature up
or down by up to 10°. For example,
OAT 3 adjust the OAT upward 3°.
T, A
EGT -
1?N
EGT
1?N
EGT
1?Y
Y—Yes—sets the digital display to
one degree resolution; N—No—sets
10°. (10° is easier to see.)
F, A
29.00
= KF
LFT
05.00
99.99
Used to set and fine tune the K
factor. See text below.
F, A
KF=
29.00
RT
05.00
99.99
Used to set and fine tune the K
factor. See text below.
F, A
ACCU
M?N
USD
ACCU
M?N
ACCU
M?Y
N—No—Upon informing the EDM-
760 that you refueled the aircraft,
reset total fuel used to 0.
Y—Yes—accumulate total fuel
used rather than reset to 0.
F, A
GPS-C
= 2
TO
GPS
0 5 GPS Com Format.
T, F, A
DUMP?
N
MEM
N
NEW
ALL
(Long Term Memory Option only.)
Select to transfers ALL or only
NEW data. (Next step is bypassed
for a Long Term Memory Option
DUMP.)
T, F, A
END
Y
END
Y
END
N
Y—Yes to exit; N—No to review list
again.
For Your Safe Flight Page 41

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the J.P. Instruments EDM-760 TWIN and is the answer not in the manual?

J.P. Instruments EDM-760 TWIN Specifications

General IconGeneral
BrandJ.P. Instruments
ModelEDM-760 TWIN
CategoryAvionics Display
LanguageEnglish

Related product manuals