JA-63 “Profi“ User manual
Internet: www.jablotron.cz
Tel.: +420 483 559 999
fax: +420 483 559 993
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic

Other manuals for jablotron JA-63 „PROFI“

Questions and Answers

  • H
    hrossAug 20, 2025
    Why does my Jablotron Security System PIR movement detector repeatedly trigger alarms?
    • T
      Todd RobinsonAug 20, 2025
      Your Jablotron Security System's PIR movement detector might repeatedly trigger alarms due to: * Animals in the protected area (like mice). * Sudden temperature changes or intense air circulation. * Movement of objects with a temperature around 37°C. To resolve this, try increasing the detector’s immunity via its internal settings, changing the detector's location, or using an optional sensor lens.
  • T
    Troy GuzmanAug 22, 2025
    What to do if my Jablotron Security System telephone dialer calls a number multiple times when activated?
    • D
      Derrick ChristensenAug 22, 2025
      If your Jablotron Security System's telephone dialer calls a number multiple times, it might be because the telephone network isn't using standard recognition signals. This makes the dialer unsure if the connection was successful. To fix this, store F0 after the last digit of the problematic number.
  • K
    Kenneth CruzAug 25, 2025
    Why does my Jablotron Security System indicate telephone line failure when the phone works normally?
    • R
      reginaldandersonAug 25, 2025
      If your Jablotron JA-65X Security System indicates a telephone line failure even when the phone works normally, it could be because the system interprets phone calls longer than 15 minutes as the telephone line not being ready. If this problem persists, disable telephone line checking in programming mode.
  • T
    trevorestradaAug 26, 2025
    How to fix a Jablotron Security System that doesn't communicate with the connected PC?
    • J
      Jordan FarleyAug 26, 2025
      If your Jablotron Security System isn't communicating with the connected PC, the PC-60A cable might not be connected to the correct COM connector on the PC. Check the connection or manually select the port number in the software.
  • J
    Jeffrey DavilaAug 27, 2025
    Why is it impossible to enroll a wireless item in my Jablotron Security System?
    • A
      Angela CrawfordAug 28, 2025
      If you cannot enroll a wireless item in your Jablotron Security System, the item's location may not be suitable, resulting in a low radio signal level. This could be due to excessive distance or an obstacle blocking communication. Try changing the item's location. Temporarily secure it in the new location first to test the connection.
  • E
    Erik BenderAug 30, 2025
    Why does my Jablotron Security System alarm after first powering on?
    • E
      erikgriffinAug 30, 2025
      If your Jablotron Security System alarms after the first power-on, it's likely because the control panel is not in the factory default setting. Perform a factory default reset to resolve this.
  • E
    emilynguyenAug 31, 2025
    Why does the connected JA-60E keypad have no function in my Jablotron Security System?
    • B
      Bonnie BeanSep 1, 2025
      If the connected JA-60E keypad has no function in your Jablotron Security System, the connecting cable may not be properly aligned. Ensure the cable connects the corresponding positions in the keypad and the control panel (1-1, 2-2, 3-3, 4-4). Check the colors of the cores in the cable and the positions on each side.
  • K
    kennethdeckerSep 2, 2025
    Why does my Jablotron Security System PIR movement detector keep triggering alarms?
    • J
      Joshua WallaceSep 2, 2025
      If your Jablotron Security System's PIR movement detector repeatedly triggers alarms without any apparent reason, consider these potential causes: * Animals might be present in the protected area. * Sudden temperature fluctuations or strong air currents could be affecting the detector. * Movement of objects with a temperature around 37°C might be triggering the sensor. To resolve this, you can increase the detector's immunity via its internal settings, relocate the detector, or try using an alternative sensor lens.
  • M
    Mary HawkinsSep 4, 2025
    What to do if my Jablotron Security System indicates telephone line failure but the phone works?
    • S
      sfergusonSep 4, 2025
      If your Jablotron Security System telephone line failure is indicated, but the phone works as normal, it could be because the system interprets phone calls longer than 15 minutes as a tel. line issue. If this problem occurs repeatedly, you can disable tel. line checking in programming mode.
  • M
    Miss Joanne DiazSep 6, 2025
    Why does the Jablotron Security System tel. dialer call a number multiple times?
    • W
      william69Sep 6, 2025
      If your Jablotron Security System, when activated, calls a number multiple times, it's likely because the telephone network isn't using standard recognition signals. As a result, the dialer can't confirm if the connection was successful. To fix this, store F0 after the last digit of the problematic number.

Summary

Indicators

LED Indicators

Explains the meaning of LED indicators on the keypad.

Display Event Source Codes

Details codes displayed on the keypad indicating event sources.

Display System Mode Codes

Details codes displayed on the keypad indicating system modes.

Controlling the System

User Codes Overview

Explains the use and programming of user codes for system control.

Master and Service Codes

Explains the roles of master and service codes for access and programming.

System Arming

Details how to arm the system using keypad or remote control.

System Disarming

Explains the procedure for disarming the system via keypad or remote.

Panic Alarm Function

Describes how to trigger the panic alarm for emergency assistance.

Stopping an Active Alarm

Explains how to stop an active alarm and its consequences.

Home Arming (Partial Arming)

Details the procedure for home arming (partial system arming).

Door Opening Control

Explains how to control an electrical door lock via the alarm system.

Alarm Memory Access

Describes how to access and view recorded alarm events.

Voice Message Listening

Explains how to listen to programmed voice messages.

Split System Arming

Describes how the system can be split into sections for independent arming.

Subsystem Enrollment

Explains how sub control panels can be enrolled to the main system.

Appliance Control

Details how to control electrical appliances via the system.

User Settings and Configuration

Setting a New Master Code

Guides on changing the master code for system supervisor.

Managing User Codes

Explains how to set, change, or delete user codes.

Setting Internal Clock

Details how to set the system's internal clock and date.

Automatic Arming;Disarming Schedules

Explains how to program automatic arming and disarming schedules.

Zone Bypassing

Describes how to bypass specific zones from triggering alarms.

Telephone Communicator Programming

Testing the Telephone Communicator

Explains how to test the telephone communicator functionality.

Voice Message Telephone Numbers

Details how to program telephone numbers for voice messages.

Automatic SMS Alert Configuration

Explains how to configure automatic SMS alerts for events.

System Maintenance and Testing

System Testing Procedures

Outlines monthly procedures for testing the alarm system.

Battery Replacement Guide

Guides on how to replace batteries in system components.

Module Enrollment (UC-2 xx)

Explains how to enroll the control panel to wireless modules.

jablotron JA-63 „PROFI“ Specifications

Power IconPower
power230 VAC
max current0.1 A
backup battery voltage12 V
backup battery capacity1.3 or 2.6 Ah
backup power output voltage13 VDC
max permanent current0.4 or 1 A
self-consumption of the control panel30 mA
Operating Environment IconOperating Environment
environmental classII indoor – general (-10 to 40 °C)
complianceEN 50131-1, EN 50131-6 security grade 2
safetyEN 60950, class II