If the (
11.) parameter is disabled, any triggered detector is bypassed
automatically no key-press confirmation is needed.
While setting (arming) the system via a key-fob controller, any triggered zone
is bypassed automatically regardless of the (
11.) parameter.
If a detector has been bypassed, it starts to protect as
soon as it is de-triggered (for example, if a door is
closed).
3. After the system has just been set (armed)
The keypad beeps and an exit delay will begin. The keypad displays
Exit delay”.
The keypad indicates which sections have been set (A; B; C).
If exit delay acoustic signalling (
6.) is enabled, the exit delay is
indicated by regular beeps from the keypad (the beeps get faster in the
last 5 seconds).
For a partially set system, the exit delay may not be signalled
acoustically (
7.).
You have to leave protected areas before the exit delay (
20) elapses.
If final-door detector mode (
12.) is triggered during an exit delay,
then the exit delay is extended to the moment when the final door is
closed. So you can set and leave the house comfortably without any
haste. If the final-door detector is not triggered, then the system
provides a normal exit delay.
4. System unsetting (disarming)
After you step into a set (armed) section, an entrance delay will begin. This is
indicated by displaying “Entrance delay” on the keypad. Also, the keypad starts
to beep fast if entrance delay acoustic signalling is enabled (
8.) (the wireless
keypad only if it is powered from the AC adaptor or the door detector is
connected to the keypad or when you open its cover). Additionally, the
entrance delay time can be indicated by an indoor siren.
During the entrance delay (
21) you have to unset (disarm) the system
by entering a valid access code (or, alternatively, presenting a valid
access card, or using a valid key-fob).
If final-door detector mode (
12.) is active and you came in through
the corresponding door, then the entrance delay would be six times
longer than if it had been triggered by an ordinary detector (i.e. if you
Oasis user manual 6 MKE22102

Other manuals for jablotron Oasis

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jablotron Oasis and is the answer not in the manual?

jablotron Oasis Specifications

General IconGeneral
CategoryAlarm System
TypeWireless
CommunicationGSM
SirenSupported
Remote ControlYes, via keyfobs and mobile app