Programming sequences beginning with the
1 sets the entire system (the same as the ABC key)
2 sets section A (the same as the A key)
1
)
3 sets A and B, or just B (the same as the B key)
1
)
4 event memory recall (key 4 scrolls backwards) – the control panel records the 255 latest events
5 new Master Code/Card (∗5 MC NC NC) (MC- master code; NC – new code)
6 access code/card programming (∗6 MC nn NC) (MC- master code; NC – new code)
7 for operation while under duress (should be entered before the access code to secretly signal distress)
8 PGX control (ON/OFF = ∗81/∗80 or enter ∗8 to trigger, if a pulsed switching reaction is
programmed)
1
)
9 PGY control (ON/OFF = ∗91/∗90 or enter ∗9 to trigger, if a pulsed switching reaction is
programmed)
1
)
0 To enter Service Mode (0∗ SC – factory default 8080) or to enter maintenance mode (0∗ MC –
factory default 1234)
1
) The functions allow the system to be operated from a mobile phone keypad (if the control panel is
equipped with the relevant communicator).