Error Code Description Solution
Err-01 Hardware
overcurrent
1Power off, restart 2Under normal condition, check voltage, low
voltage is 176 v, high voltage is 264 v 3Turn the handwheel to see
whether mechanical parts is stuck 4Check the motor plug 5Factory
resettest the motor angle 6Replace the electronic control box
Err-02 Software
overcurrent
Err-03 system under
voltage
Err-04 Over-voltage when
the machine is
off
Err-05 Over-voltage in
operation
Err-06 Magnet circuit
fault
1Check whether the plug, pin is fall off2Unplug the electromagnet
plug to see if is still in an error 3Replace the electromagnet4
Replace the electric control
Err-07 Power measuring
detection
circuit fault
1factory reset2Replace the electric control
Err-08 Sewing motor
blocked
1Turn the handwheel to see whether mechanical parts is stuck 2Check
the motor plug
3Factory resettest the motor angle 4Replace the motor 5Replace
the encoder6Replace the electric control