EasyManua.ls Logo

Jacobsen Eclipse 322

Jacobsen Eclipse 322
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 LDU ERROR CODES
en-104
Generator temperature greater than
340° F (171° C). Engine speed is set
to idle.Shut mower down and wait
ten minutes. Restart mower. If fault
returns, return mower to
maintenance shed.
44 444
Generator temperature less than
-20° F (-29° C). Engine speed is set
to idle. Allow engine to run until
generator warms up.
44 444
Rectifier temperature greater than
340° F (171° C). Engine speed is set
to idle.Shut mower down and wait
ten minutes. Restart mower. If fault
returns, return mower to
maintenance shed.
44 444
Rectifier temperature less than -20°
F (-29° C). Engine speed is set to
idle. Allow engine to run until
generator warms up.
44 444
Current sense fault. Current less
than 20A when engine above 2900
rpm. Restart mower. Return to
maintenance shed.
44 444
LDU Error Code Description
Caution
LED
Alarm
Sounding
Engine
Stop
Traction
Stop
Mow Stop
On Off Yes No Yes No Yes No Yes No
GENERATOR
FAULT 56
GENERATOR
FAULT 57
GENERATOR
FAULT 58
GENERATOR
FAULT 59
GENERATOR
FAULT 88

Table of Contents

Other manuals for Jacobsen Eclipse 322