EasyManua.ls Logo

Jacuzzi J-135

Jacuzzi J-135
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
J-100
16.0 Circuit Board Diagrams
16.1 North American J-135 and J-145 Models
This wiring diagram is used for the 240V 60 Hz North American spa
models.
DANGER
Turn power off
before servicing. This
task should only be
performed by a quali
-
fied technician.
!
RISK OF SHOCK OR
ELECTROCUTION!
CLEARRAY
PUMP 1
2 SPEED
1
2
3
4
OZONE
PUMP 1
PUMP 2
UV
A/V
30A
30A
240VAC, 26A/36A/45A
3-WIRE CONNECTION
60HZ 1-PHASE SERVICE
RED
BLK
G-GRN
STEP LIGHT
(OPTIONAL)
WATER
SENSOR
5.5 kW HEATER
THERMAL CUTOFF
PUMP 2
FLOW
SENSOR
5AT~250V
LIGHT
ADAPTER
CONTROL PANEL
S1
ON
1 2 3 4 5 6 7 8 9 10
46

Table of Contents

Related product manuals