30
lowed by the number of minutes the function will remain blocked.
XThis function will end after 60 minutes or by pressing and
holding the “Light”
key for about 5 seconds.
NOTES
- If a ltering cycles is active, it will restart 40 minutes after the end
of the stand-by condition at the same point it was stopped. This
means that if 1 hour remained when the cycle was stopped, when it
restarts it will operate for this amount of time and then stop.
- If the heater was on when stopped, it is turned o immediately
and water is circulated for 30 seconds in order to cool the heating
element.
Abnormal operating conditions
- alarm signals -
Alarms are indicated on the display, with the corresponding error code.
You will continue to see the code if the alarm condition persists.
XSignals on display
- possible solution
XFLOThe ow switch does not detect the water (the heater can-
not be turned on).
The cartridge lter and/or pump may be clogged, or the ow switch
may have been installed in the wrong direction with respect to the
normal ow of water. The alarm may also appear if the ow switch
is faulty.
- Contact an authorized Jacuzzi® service centre.
XHOH The temperature is higher than or equal to 48 °C (118 °F)
(the heater is turned o).
DO NOT ENTER THE WATER
This alarm, which is displayed alternating with the time and temper-
ature, will disappear as soon as the value drops below 44 °C (111 °F).
- If the alarm condition persists, try turning the switch up the line
from the hot tub o and back on. If the signal stays on, contact
an authorized Jacuzzi® service centre.
XHoExcessive water temperature
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 44 °C (111 °F). It is
not possible to activate any function.
- If present, remove cover from hot tub.
- If the excessive temperature increase is due to sunlight, add
cold water to the hot tub.
When the temperature has dropped to below 43 °C (109 °F), the
hot tub should re-activate automatically. If it does not, discon-
nect the power supply and contact an authorized Jacuzzi ® ser-
vice centre.
XH2OWater level too low.
It’s not possible to activate the pump.
- Fill with water until the message disappear.
XrPFDefective temperature probe
DO NOT ENTER THE WATER
It is not possible to activate any function.
- Check that the temperature probe is working, or replace it.
XHPF Activation of safety thermostat.
It is not possible to turn on the heater (overheating, this could be due
to irregular water ow).
- Try turning the switch up the line from the hot tub o and back
on (system reset). If the signal stays on, contact an authorized
Jacuzzi® service centre.

Table of Contents

Other manuals for Jacuzzi Lodge L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi Lodge L and is the answer not in the manual?

Jacuzzi Lodge L Specifications

General IconGeneral
BrandJacuzzi
ModelLodge L
CategoryHot Tub
LanguageEnglish

Related product manuals