Jacuzzi
®
Magnum, RC, LR, Cygnet
E-1451
Owner’s Manual
Before installation, be sure to read all instructions
and warnings carefully.
Refer to product dataplate(s) for additional operating
instruction and specifications.
Inspection
Examine the equipment when received. Notify your
dealer or carrier of any damage or missing parts. Verify
that equipment is of size and model specified.
Important Safety Instructions
When installing and using this electrical equipment,
basic safety precations should always be followed,
including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. WARNING – To reduce risk of injury, do not permit
children to use this product unless they are closely
supervised at all times.
3. WARNING – (For cord & plug connected units). Risk
of Electrical Shock. Connect only to a grounding type
receptacle protected by a ground-fault circuit-
interrupter (GFCI). Contact a qualified electrician if
you cannot verify that the receptacle is protected by a
GFCI.
4. WARNING – (For cord & plug connected units). Do
not bury cord. Locate cord to minimize abuse from
lawn mowers, hedge trimmers and other equipment.
5. WARNING – (For cord & plug connected units). To
reduce the risk of electric shock, replace damaged
cord immediately.
6. WARNING – (For cord & plug connected units).
To reduce the risk of electrical shock do not use an
extension cord to connect unit to electrical supply;
provide a properly located outlet.
7. CAUTION – (For pumps with a 25 ft. (7.62m cord).
This pump is for use with storable pools only. Do
not use with permanently installed pools. A storable
pool is constructed so that it may be readily
disassembled for storage and reassembled to its
original integrity. A permanently installed pool is
constructed in or on the ground or in a building such
that it cannot be readily disassembled for storage.
8. CAUTION – (For pumps with/without 3ft. (.91m
cord). This pump is for use with permanently
installed pools and may also be used with hot tubs
and spas if so marked. Do not use with storable
pools. A permanently installed pool is constructed
in or on the ground or in a building such that it
cannot be readily disassembled for storage. A
storable pool is constructed so that it may be readily
disassembled for storage and reassembled to its
original integrity.
9. WARNING – (For hot tub and spa pumps). Do not
install within an outer enclosure or beneath the skirt
of the hot tub or spa, unless so marked.
10. SAVE THESE INSTRUCTIONS!
Installation Location
Locate pump as close to pool/spa as possible,
preferably in a dry, well ventilated area away from direct
sunlight. It should be on a hard, level surface. Give
consideration to:
should be on a hard, level surface. Give consideration to: the pump discharge. The valves are essential for pump
Question and Answer IconNeed help?

Do you have a question about the Jacuzzi Magnum and is the answer not in the manual?

Jacuzzi Magnum Specifications

General IconGeneral
Horsepower1.5 HP
Voltage115/230V
Flow Rate90 GPM
Inlet/Outlet Size2 inches
MaterialPlastic
Port Size2 inches
PhaseSingle

Summary

Inspection and Safety

Equipment Inspection

Examine equipment upon receipt, notify dealer of damage, and verify model and size.

General Safety Precautions

Follow all instructions and basic safety precautions when installing and using electrical equipment.

Child Supervision

Ensure children are closely supervised when using the product to reduce the risk of injury.

Electrical Shock Prevention

Connect cord & plug units only to GFCI protected receptacles to prevent electrical shock.

Cord Protection and Safety

Avoid burying cords and replace damaged ones immediately to prevent shock and damage.

Outlet and Extension Cord Usage

Do not use extension cords; ensure a properly located outlet for electrical supply to prevent shock.

Pool Type Compatibility

Use pumps for specified pool types: storable pools only or permanent pools, hot tubs, and spas.

Hot Tub/Spa Pump Installation

For hot tub and spa pumps, avoid installation within outer enclosures or beneath the spa skirt unless marked.

Installation Location

Place pump near pool, in dry, ventilated area, away from sun, on a hard, level surface.

Plumbing and Electrical Setup

General Plumbing Guidelines

Use correct adhesives for PVC, consider climate, and use Teflon tape for threaded connections.

Pump Plumbing Best Practices

Keep piping straight, short, sloped upward, and supported; minimize suction lift and use valves for servicing.

Electrical Service Requirements

Follow nameplate data, use disconnects/breakers, ensure correct wire size, and hire a qualified electrician.

GFCI Protection Recommendation

Install a ground fault circuit interrupter (GFCI) for maximum safety when connecting electrical supply.

Pump Operation and Maintenance

Pump Start-Up Procedure

Always prime the pump before operation, as water cools and lubricates the seal. Follow specific priming steps.

Post-Startup Leak Check

Check return fittings for air bubbles after operation; continuous air indicates suction leaks needing correction.

Controlling Pump Output

Keep suction valves open; use return line valves to control pump output.

Two-Speed Pump Usage

Utilize high speed for peak filtration/turbidity and low speed for normal operation or filtration cycles.

Troubleshooting and Winterizing

Trouble Shooting Guide

Provides solutions for common issues like motor not starting, low speed, overheating, and no water delivery.

Winterizing Procedures

Consult dealer for advice; drain system by loosening drain plugs or removing pipe caps.

Water Chemistry Maintenance

Maintain clean water using chemicals like chlorine and keeping pH levels between 7.2-7.4.

Pump Maintenance Tasks

Motors are self-lubricating; clean hair/lint strainer; visually inspect motor vents; check shaft seals.

Limited Warranty Information

Product Warranty Coverage

Warrants products against defects for 1 year from installation or 3 years from manufacture.

Warranty Limitations

Excludes damage from misuse, accident, or improper installation; limits liability for incidental damages.