7. Warranty/Service
Your blood pressure monitor is guaranteed for 2 years against manufacturers’
defects for the original purchaser only, from date of purchase. The warranty
does not apply to damage caused by improper handling, accidents,
professional use, not following the operating instructions or alterations made
to the instrument by third parties.
Warranty only applies to the main device and its cuff. All other accessories
are not covered by warranty.
There are no user serviceable parts inside. Batteries or damage from old
batteries is not covered by the warranty.
8. Certifications
Device standard:
This device is manufactured to meet the European blood pressure monitors:
IEC 80601-2-30 / IEC60601-1-11 / IEC60601-1
Electromagnetic compatibility:
Device fulfills the stipulations of the International standard
IEC60601-1-2
9. Technical Specifications
11. EMC Declaration
1) *This product needs special precautions regarding EMC and needs to be
installed and put into service according to the EMC information provided, and
this unit can be affected by portable and mobile RF communications
HTXLSPHQW
2) * Do not use a mobile phone or other devices that emit electromagnetic
fields, near the unit. This may result in incorrect operation of the unit.
3) * Caution: This unit has been thoroughly tested and inspected to assure
SURSHUSHUIRUPDQFHDQGRSHUDWLRQ
4) * Caution: this machine should not be used adjacent to or stacked with
RWKHUHTXLSPHQWDQGWKDWLIDGMDFHQWRUVWDFNHGXVHLVQHFHVVDU\WKLV
machine should be observed to verify normal operation in the configuration in
which it will be used
10. FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
Measuring method: Oscillometric
Pressure sensor: Resistive
Measuring range: DIA: 40-220mmHg; SYS: 60-260mmHg
Pulse: 40 to 199 per minute
Cuff pressure display range:0-295mmHg
Memory: Automatically stores the last 120 measurements for 2 users (total
240)
Measuring resolution: 1 mmHg
Accuracy: Pressure within ± 3 mmHg / pulse ± 5 % of the reading
Power source: Built-in high capacity lithium battery - 800mAh
b) AC adapter INPUT: a.c. 100-240V= 50/60HZ OUTPUT: d.c. 5V 1A
Accessories: Wide range rigid cuff 8.7” – 16.5” (22 - 42 cm)
Users: Adult
Expected service life of the device and accessories: 5 years
7HFKQLFDODOWHUDWLRQVUHVHUYHG
Model: BC31L/BC31LT
Weight: 259g (battery is not included)
Display: 132×55mm(5.2"×2.17") LED Digital Display
Size: 164(L)×88(W)×69(H) mm(6.46"×3.46"×2.72")
Packaging list: 1×Main Device, 1×Cuff, 1×Users manual,
Operating Conditions: Temperature: 5 to 40;Humidity: 15% to 93% RH;
Storage And Shipping Conditions:Temperature: -25 to 70;
+XPLGLW\5+
Atmospheric pressure range: 70kPa~106kPa
IP classificationIP21