Installation Data
Installation Man u al
PDA - Pool Digital
Assistant
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/spa service
technician. The procedures in this manual must be followed ex act ly. Failure to follow warning notices
and instructions may result in property damage, serious injury, or death.
Pool/Spa Combination Systems and
Pool Only/Spa Only Systems
(Models PS4, PS6, PS8, P4, and P8)
Firmware Revision 2.6
H0572200B
ATTENTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an electrical source on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Modi cations made to this equipment, which are not authorized by the manufacturer, may void the user’s authority
to operate this equipment.

Questions and Answers

  • D
    David McbrideAug 17, 2025
    Why are my Jandy and P8 Control Systems programs not running at the correct time?
    • S
      sarahzhangAug 17, 2025
      If your Jandy Control System programs aren't running at the correct time, it's likely that the AquaLink RS is displaying an incorrect time and date. To fix this, set the correct time and date on the PDA Handheld Remote. Also, check the battery level in Diagnostics. If 'LOW BATTERY' is displayed, replace the battery at the Power Center to ensure the correct time and date are maintained.
  • T
    tammy31Aug 20, 2025
    Why won't my Jandy Control Systems heater fire?
    • M
      Mrs. Ariana Washington DDSAug 20, 2025
      If the heater in your Jandy Control System will not fire and the heater LED doesn't light up in 'Service Mode', the water temperature sensor may not be installed or could be defective. Check the water temperature sensor.
  • K
    kathy73Aug 23, 2025
    What to do if my Jandy Control System is locked up?
    • G
      gregorygibsonAug 23, 2025
      If your Jandy Control System is locked up, it may be due to a microprocessor lock. To resolve this, turn off the power to the system. Disconnect the battery at the Power Center, then turn the power back on. Reconnect the battery and reset the time and date.
  • B
    brownjamesAug 26, 2025
    How to fix Jandy and P8 override switches that don't operate?
    • N
      Nicholas FosterAug 26, 2025
      If the override switches on your Jandy Control System power center aren't working, it could be due to a damaged or improperly installed PPD, the wrong PPD, or a damaged power center PCB. Here's what to check: 1. Ensure the PPD is correctly aligned. 2. Verify that the PPD is designed for a PDA. 3. If the PPD is correctly installed, consider replacing the power center PCB.
  • A
    Anne JenkinsAug 28, 2025
    Why does my Jandy Control System come on at times that are not programmed?
    • R
      ryandanielsAug 28, 2025
      If your Jandy Control System comes on at times that are not programmed, it may be due to phantom programs. Here’s how to resolve it: 1. On the PDA, press MENU, then select PROGRAM. Note all program settings (Four Function Remote setting, labels, and temperature settings). 2. Turn off all DIP switches. 3. Go to the PDA and CLEAR MEMORY. 4. Reprogram the system and test.
  • C
    calvin92Aug 30, 2025
    What to do if some Jandy Control Systems buttons do not operate?
    • D
      Dr. Tanya Fuentes MDAug 31, 2025
      If some buttons on your Jandy Control System's PDA Handheld Remote or power center override switches aren't working, it might be due to the wrong PPD chip installed on the power center PCB. Ensure the PPD revision number is correct for your application.
  • N
    Nicole GonzalesSep 2, 2025
    How to fix a completely dead Jandy Control Systems PDA Handheld Remote?
    • J
      Jeffrey MannSep 2, 2025
      If the PDA Handheld Remote for your Jandy Control System is completely dead (no backlight or display), the batteries are likely dead. Replace the batteries to resolve this issue.
  • G
    garcianathanSep 5, 2025
    Why does my Jandy and P8 Control Systems pool cleaner booster pump turn on without the filter pump?
    • D
      Donald ClaytonSep 5, 2025
      If your Jandy Control System's pool cleaner booster pump turns on without the filter pump or runs with the spa on, the system may not be recognizing that DIP switch #1 is on. To fix this: 1. Turn off all equipment buttons. 2. Turn off the power to the system. 3. Turn DIP switch #1 off, then on again. 4. Turn the power back on and test the system.
  • A
    Anna MartinezSep 8, 2025
    Why does my Jandy and P8 Control Systems LCD screen stay on the startup screen?
    • T
      Tyler BarronSep 8, 2025
      If the LCD screen display on your Jandy Control System stays on the startup screen, there may be no communication between the PDA Handheld Remote and the Power Center J-box. Change the Frequency Channel. See Section 3.7.3.
  • T
    Thomas GriffinSep 12, 2025
    What to do if Jandy and P8 PDA is not communicating with the power center PCB?
    • M
      Michelle ArroyoSep 12, 2025
      To solve communication issues between the PDA and the power center PCB in your Jandy Control System, check the two center wires (black & yellow) of the four-conductor cable to the transceiver J-box. Also, check the installation of the PPD on the power center PCB. The system will not communicate if the PPD is not seated correctly.

Summary

Important Safety Instructions

Risk Reduction and Health Hazards

Covers hyperthermia, water temperature, alcohol/drug use, medical conditions, and children's safety.

Electrical Safety and Grounding

Details electrical shock risks, grounding requirements, and GFCI usage for lighting.

Installation

Power Center Mounting

Guidelines for securely mounting the Power Center unit.

High Voltage Wiring

Instructions for connecting high voltage power supply to the system.

Heater Connection

Instructions for connecting various types of heaters to the system.

Changing the Frequency Channel

How to change RF channel to avoid interference with other systems.

System Startup

Handheld Remote Programming

Guide to programming the system using the handheld remote.

Basic Programming Menu

Steps to program equipment ON/OFF times and schedules.

Set Freeze Protection Menu

Configuration of freeze protection temperature and device assignments.

Troubleshooting

PDA Quick Troubleshooting Guide

Table listing common PDA communication and operation issues and their solutions.

Power Center Wiring Diagram

Power Center PCB DIP Switch Settings

DIP Switch Functions

Detailed explanation of each DIP switch and its function.

DIP Switch Settings for Pool and Spa Combination

Recommended DIP switch configurations for Pool/Spa systems.

DIP Switch Settings for Pool or Spa Only

Recommended DIP switch configurations for Pool Only or Spa Only systems.