Troubleshooting Data
Troubleshooting Manual
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/
spa service technician. The procedures in this manual must be followed ex act ly. Failure to
follow warning notices and instructions may result in property damage, serious injury, or
death.
Pool/Spa Combination Systems
Pool/Spa Only Systems
Dual Equipment Systems
AquaLink
®
RS
All Button and
OneTouch
Control Systems
6919E

Other manuals for Jandy AquaLink RS6

Questions and Answers

  • P
    Peter ThompsonAug 17, 2025
    What to do if my Jandy Control Panel system locked up?
    • T
      tcoxAug 17, 2025
      If your Jandy Control Panel system has locked up, it may be due to a locked microprocessor. To resolve this, turn off the power to the system, disconnect the battery, and turn the power back on. Then, reconnect the battery and reset the time and date.
  • R
    Riley MatthewsAug 19, 2025
    Why are my Jandy Control Panel programs not running at the correct time?
    • J
      Joseph RussellAug 20, 2025
      If programs on your Jandy Control Panel are not running at the correct time, it's likely that the AquaLink system is displaying an incorrect time and date. To fix this, set the correct time and date on the control panel. Also, check the battery level in Diagnostics. If 'LOW BATTERY' is displayed, replace the battery to ensure the correct time and date are maintained.
  • M
    Mrs. Emily DeanAug 22, 2025
    What to do if Jandy Control Panel is dead but override switches work?
    • O
      Oscar FryAug 22, 2025
      If the Power Center override switches operate in Service or Time Out Mode, but the Jandy Control Panel is dead (no lights or display), it indicates a power supply problem. Check the connection of the outside two wires (red & green) of the four-conductor cable. If wired correctly, check the voltage between these two wires. For an All Button system, the voltage should be 7+ VDC, and for a OneTouch system, 8+ VDC (use the higher voltage for a mixed system).
  • L
    Lisa GarciaAug 26, 2025
    Why is my Jandy Control Panel showing all LEDs on but not communicating?
    • D
      David HartAug 26, 2025
      If all LEDs are on at the Jandy Control Panel, and the part # and revision letter of the control panel software are displayed, but the control panel is not communicating with the power center PCB, check the two center wires (black & yellow) of the four-conductor cable. Also, check the installation of the PPD on the power center PCB. If the PPD is not seated correctly, the system will not communicate.
  • J
    Joanna MorrisAug 28, 2025
    How to fix Jandy Control Panel when pool cleaner runs without filter pump?
    • T
      Teresa SteinAug 28, 2025
      If the pool cleaner booster pump turns on without the filter pump being on, and can run with the spa on in your Jandy Control Panel system, it indicates that the system isn't recognizing that DIP switch #1 is on. To resolve this, turn off all equipment buttons, then turn off the power to the system. Turn DIP switch #1 off, then on again. Finally, turn the power back on and test the system.
  • M
    Matthew GibbsAug 31, 2025
    Why some buttons on my Jandy Control Panel don't work?
    • B
      Brianna GonzalezAug 31, 2025
      If some buttons do not operate from the Jandy Control Panel or the power center override switches, it may be due to the wrong PPD chip installed at the power center PCB. Check the part number and revision letter by pressing the reset button at the control panel. The second part number and revision letter displayed is for the PPD indicating which model.
  • S
    Sue BakerSep 2, 2025
    What to do if all LEDs are on but override switches don't work on Jandy Control Panel?
    • C
      Caitlin BartonSep 2, 2025
      If all LEDs are on at the Jandy Control Panel and the part # and revision letter are displayed, but override switches at the power center do not operate, it could be due to: 1. A damaged or improperly installed PPD. 2. A damaged power center PCB. First, check the alignment of the PPD. If the PPD is installed correctly, replace the power center PCB.
  • K
    Kristine FrankSep 5, 2025
    Why is my Jandy Control Panel RS system slow or display erratic?
    • E
      Edward GraySep 5, 2025
      If the RS System operation is slow or the display is erratic on your Jandy Control Panel, it's likely due to older firmware being installed. To resolve this, replace the socketed chip in the OneTouch printed circuit board with Firmware B11 or newer.
  • C
    Christopher AndersonSep 8, 2025
    Why does my Jandy Control Panel LCD screen stay on 'Firmware B11'?
    • E
      Eddie ChavezSep 8, 2025
      If the LCD screen display stays on 'Firmware B11' (or later) on your Jandy Control Panel, there may be no communication between the indoor Control Panel and the Power Center J-box. Confirm that the DIP switch settings on both the Indoor Control Panel Transceiver and Power Center Transceiver are as follows: - DIPs 1-7 are set identically - DIP 8 is ON at the Power Center J-box PCB - DIP 8 is OFF at the Control Panel Transceiver PCB.
  • T
    Taylor GoodwinSep 12, 2025
    What to do if one button on Jandy Four Function Remote doesn't operate?
    • J
      Jordan BallSep 12, 2025
      To address a non-operational button on the Four Function Remote or SpaLink RS of your Jandy system, replace the Four Function Remote or SpaLink RS. Use MENU, REVIEW, SPA SWITCH (or SPA LINK) to check programming.

Summary

Section 1. Important Safety Instructions

Section 2. Control Panel Overview

2.1 Indoor Control Panel

Description of the indoor control panel's functions and features.

2.2 Controller

Details on the controller's power supply and communication.

2.3 Reset Switch

Information on using the reset switch for diagnostics and resets.

Section 3. Controller

3.1 Diagnostics

Steps to access and interpret diagnostic information for the controller.

3.2 Controller Troubleshooting

Troubleshooting steps for common controller problems like no display.

3.3 Heater Operation

Explains heater operation indicators and troubleshooting for heating issues.

Section 4. Power Center

4.1 Overview

Explanation of the power center's role, driver chips, and memory.

4.2 Power Center Troubleshooting

Steps for troubleshooting power loss and transformer issues.

4.3 Main Power Center PCB

Details on the main power center PCB layout and components.

Section 5. Auxiliary Power Center

5.1 Overview

Description of auxiliary power center functions and components.

5.2 DIP Switches

Configuration settings for DIP switches on the power center.

5.3 Water Temperature Sensor

Troubleshooting and resistance chart for the water temperature sensor.

5.4 3 HP Relay

Details on the operation and specifications of the 3 HP relay.

5.5 Two Speed Relay

Explanation of the two-speed relay's operation and wiring.

5.6 Light Dimming Relay

Operation and wiring of the light dimming relay for pool lights.

Section 6. Jandy Valve Actuator

6.1 Operation

Explains how the Jandy Valve Actuator operates and its internal wiring.

Section 7. Troubleshooting

7.1 Quick Check List

A quick checklist for common troubleshooting symptoms and solutions.

7.2 Controller Inoperable, Display Blank

Flowchart to diagnose and fix a controller with a blank display.

7.3 All Lights Lit on Controller

Troubleshooting guide for when all controller lights are on but it's unresponsive.

7.4 Some Controller Buttons Do Not Operate

Steps to troubleshoot unresponsive buttons on the controller.

7.5 Three Amp Fuse Keeps Failing

Diagnostic steps for a repeatedly failing 3 amp fuse.

7.6 Heater Doesnt Fire

Troubleshooting steps for when the heater is not operating.

Section 8. Flow Charts

8.1 OneTouch Menu Flow Chart

Visual guide to navigating the OneTouch controller menu options.

8.2 All Button Menu Flow Chart

Visual guide to navigating the All Button controller menu options.

8.3 All Button Cancel Flow Chart

Flowchart detailing how to cancel functions on the All Button controller.

Section 9. Wiring Diagrams

9.1 AquaLink RS Pool;Spa Combination and Pool;Spa Only

Wiring diagram for Pool/Spa Combination and Pool/Spa Only models.

9.2 AquaLink RS Dual Equipment

Wiring diagram for AquaLink RS Dual Equipment models.

9.3 AquaLink RS Auxiliary Power Center

Wiring diagram for the AquaLink RS Auxiliary Power Center.

Section 10. Power Center Bezel

LIMITED WARRANTY

Jandy AquaLink RS6 Specifications

General IconGeneral
BrandJandy
ModelAquaLink RS6
CategoryControl Systems
LanguageEnglish