TruFit Bubbler | Owner’s Manual
ENGLISH
Page 7
Hydraulic Cement
12 VAC Transformer listed/certified for
pool/spa equipment or Junction Box
From Main Power
Baja Bench/Walkout
48” (122 cm)
Minimum
48” (122 cm)
Minimum
J-Box Height
Above Water Line
Follow all NEC and local codes
J-Box Height
Above Water Line
Follow all NEC and local codes
Recommended Minimum
24” (61 cm)
to help avoid turbulance
Recommended Lens Depth
to Water Line
2.5"-6" (5-15 cm)
4" minimum depth to the
top of the light lens.
From Pump Discharge/Manifold
Recommended minimum distance
from wall or other bubblers
36” (91 cm)
to help avoid swirling and turbulance
The bubbler face must be completely snug and flush
with the pool wall/surface without any protrusions.
Baja Bench Walkout
Plaster
Cement